ASTM Standards:2 This practice applies only to monolithic, laminated, or C Specification for Flat Glass insulating glass constructions of rectangular. ASTM E • Provides a conservative glass thickness procedure. ▫ Flat Glass Plates. ▫ Uniform Pressure Loads. • All publicized problems with HS ceramic. a result, some glass sizes may meet ASTM E for a given wind load but not be acceptable due to safety and manufacturing concerns. Note these tables are.

Author: Shamuro Zulumuro
Country: Azerbaijan
Language: English (Spanish)
Genre: Video
Published (Last): 28 June 2009
Pages: 499
PDF File Size: 12.50 Mb
ePub File Size: 5.58 Mb
ISBN: 985-2-44711-568-1
Downloads: 79066
Price: Free* [*Free Regsitration Required]
Uploader: Jushura

Determination and Report of Procedures. The glass has been properly glazed, without any edge damage. The final thickness and type of glass selected also depends upon a variety of other factors see 5.

Insulated Glass Units are made with two or more lites of glass with a hermetically sealed space filled with dry air or zstm gas. The single source for information on designing, specifying and building with commercial glass. This practice shall not apply to other applications including, but zstm limited to, balustrades, glass floor panels, aquariums, structural glass members, and glass shelves. The number of glass edges supported.

This practice assumes that 1 the supported glass edges for two, three, and four-sided support conditions are simply supported and free to slip in plane; 2 glass supported on two sides acts as a simply supported beam; and 3 glass supported on one side acts as a cantilever.

Accommodating for f1300 and snow is one of the important upfront considerations in the design and specification process. The design load needs to be in psf or kPa. D Practice for Plastics: In addition, considerations set forth in building codes along with criteria presented in safety-glazing standards and site-specific concerns may control the ultimate glass type and thickness selection.

Pure glass is incredibly strong — it only scratches or breaks because of imperfections that can occur 1e300 the manufacturing process. Active view current version of standard. Work Item s – proposed revisions of this standard. The assumptions and calculations result in these basic design procedures that should be followed:. Related posts you may also enjoy. It also weighs the asgm. Link to W1300 This link will always route to the current Active version of the standard.

Basic Design Procedures The assumptions and calculations result in these basic design procedures that should be followed: The specified design load shall be used for this calculation. IGUs reduce the likelihood of interior condensation forming by providing a thermal barrier atsm the inside and the outside.

Designing Glass to Resist Wind and Snow Loads

Invalid Email Address From Name: The values given in parentheses are for information only. However, some applications can be two-sided support, such as Butt Joint Glazing or sometimes even three-sided or one-sided supports.

This practice does not address aesthetic issues caused by glass deflection. This practice shall not apply to other applications including, but not limited to, balustrades, glass floor panels, aquariums, structural glass members, and glass shelves.

The glass type factor, which is the multiplying factor for adjusting the load resistance of different glass types. Thermal or insulation improvements achieved with an IGU work day and night in both summer and winter conditions, reducing heat entry and heat loss. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. If the load resistance is less than the specified design loading, or if the center of glass deflection is excessive, then the trial design needs to be modified and re-tested.

ASTM E – 09 Standard Practice for Determining Load Resistance of Glass in Buildings

About The Education Center Resources. Designing Glass to Resist Wind and Snow Loads Accommodating for wind and snow is one of the important upfront considerations in the design and specification process.

The procedures operate under some basic assumptions related to glass fabrication and installation, including: First, the impact of wind and snow ashm a building can be significant, which is why the design requirements must be followed carefully.

The thermal barrier makes interior spaces more comfortable as it is easier to maintain a consistent indoor environment. It is the responsibility e13000 the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

This practice does not consider the effects of deflection on insulating glass unit seal performance.

ASTM E – 16 Standard Practice for Determining Load Resistance of Glass in Buildings

D Practice for Plastics: The resulting load resistance, which is the uniform load that a glass construction can sustain without breaking. For example, orange, red, yellow and violet colored glasses cannot be produced using standard float technology. This practice does not apply to glass with e13300 or edge treatments that reduce the glass strength.

Appendix X1 and Appendix X2 provide additional procedures to determine maximum lateral deflection for glass simply supported on four sides. Appendix X1 provides additional procedures to determine maximum lateral deflection for glass simply supported on four sides. Historical Version s – view previous versions of standard. Appendix X3 presents a procedure to compute approximate probability of breakage for annealed AN monolithic glass lites simply supported on satm sides.

It has a light green tint, astk can be seen when held against a white background. Link to Active This link will always route to the current Active version of the standard.

Glass Education Center The single source for information on designing, specifying and building with commercial glass. Glass deflections are to be reviewed.

The procedures operate under some basic assumptions related to glass fabrication and installation, including:. These factors include but are not limited to: The relative strength of glass for a given thickness, width, height and number of supported edges. About The Education Center. Short and long duration uniform loads.