ASTM E313 EBOOK

ASTM E Calculating Yellowness and Whiteness Indices from Instrumentally. Measured Color Coordinates. This practice provides numbers that correlate. 1 Jan ASTM E Standard Practice for Calculating Yellowness and Whiteness Indices from Instrumentally Measured Color Coordinates. 14 Jan Yellowness indices are used chiefly to measure these types of degradation. Yellowness Index per ASTM Method E is calculated as follows.

Author: Zugal JoJoll
Country: Burundi
Language: English (Spanish)
Genre: Photos
Published (Last): 22 January 2005
Pages: 293
PDF File Size: 20.25 Mb
ePub File Size: 3.46 Mb
ISBN: 815-8-55969-842-8
Downloads: 60138
Price: Free* [*Free Regsitration Required]
Uploader: Dijora

This practice provides numbers that correlate with visual ratings of yellowness or whiteness of white and near-white or colorless object-color specimens, viewed in daylight by an observer with normal w313 vision. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Test sample packaging, handling, and preparation preferably no cleaning can affect the test results by modifying the surface of the sample.

Some standards addressing the visual estimation of color and astm e313 difference are Practices DDEastm e313 Eand Guide E Rick Beets, Bristolite President, demonstrates the resilience of Tufflite astm e313 customers.

Yellowness Index (YI) ASTM E313

Need help or have astm e313 question? This test is most commonly used to evaluate color changes in a material caused by real or simulated outdoor exposure.

A new, pending ASTM skylight fall protection drop test requires dropping a lb sand filled canvas bag with a 5. Gladiator Safety Screen installed on a wood curb supports two lb loads in opposing corners and a lb load in the astm e313 for a e13 static load of lb. We will keep you advised of industry and energy conservation news, and code changes that affects our mutual business. astm e313

Norma ASTM Ee1

Our mission astm e313 Bristolite is to provide satm customers with the highest astm e313 products and supreme service at an exceptional value. Certification Formally confirming that your products and services meet all trusted external and internal standards. For yellowness measurement, this practice is limited to specimens having dominant wavelength in the range to nm, or Munsell hue Image 1.

Goetz Avenue, Santa Ana, California Rick Beets, Bristolite President, demonstrates the impact resistance of Tufflite for customers. Whether your business is local or global, we can ensure your astm e313 meet quality, health, environmental, safety, and social accountability standards for virtually any market around the world.

Since YI testing astm e313 often a series of comparative measurements over extended periods of time, these factors should be defined and documented prior to any testing.

Testing Evaluating how your products and services meet and exceed quality, safety, sustainability and performance standards. White textiles, paints, and plastics are a few of the materials that can be described by the indices of yellowness or whiteness calculated by this practice. Multiple samples should be measured and the readings averaged.

It is the responsibility of the user astm e313 this standard to establish appropriate astm e313 and health practices and determine the applicability of regulatory limitations prior to use.

Formally confirming that your products and services meet all trusted external and internal standards. Send us a request Need help or have a question? For whiteness measurement, this practice is astm e313 to specimens having Munsell astm e313 greater than 8. This practice provides recommended equations for such scales and discusses their derivations and uses, and limits to their applicability see also Ref 1 2.

What is Third Party Certification and Accreditation for the food industry? Negative load cycling from Enabling you to identify and mitigate the astm e313 risk in your operations, supply chains and business processes. Some standards astm e313 the visual estimation of color and color difference are Practices DDEand Eand Guide E Positive load cycling from Astmm use of astm e313 practice is to compare specimens of e3113 same material and same astm e313 appearance.

Yellowness Index is a number calculated from spectrophotometric data that describes adtm change in color of a test sample from clear or white to yellow. Because astn observing conditions can vary widely, users should compare calculated indices with visual estimates to ensure applicability.

Global Reach Intertek is the industry leader with over 43, people in 1, locations in over countries. Inspection Validating the specifications, value and safety of your raw materials, products and assets.

Through our network of over astm e313, people in 1, laboratories and offices in countries, Intertek provides quality and safety solutions to a wide range of industries around the world.

For near-white specimens, however, it is often useful to calculate single-number scales of yellowness or whiteness.

For whiteness measurement, this practice is limited to specimens having Munsell value greater than 8. Trituff Copolyester Supports 1, lb. White textiles, paints, astm e313 plastics are a few of the materials that can be described by the indices of yellowness or whiteness calculated by this practice.

Atsm to Active This link will always route to the current Astm e313 version of the standard.

Send us a request Wilton UK: Select enough w313 or specimen areas to provide an average result that is representative of each sample astm e313 be tested.